What the camera saw, and the fix for it
Get a flue repair plan
Tell us what your report found, or that you need the camera first. We call back to set the visit.
Reading a camera frame
Every frame on our report carries a height and a caption. The ones that lead to repairs tend to look alike: a dark line running up a tile, a step where one tile sits off the one below, a joint where the camera light falls on bare brick, or a crust of glazed tar so thick the tile cannot be seen. Each is a gap between the fire and the wood framing a few inches away.
NFPA 211 expects a flue to hold heat and smoke all the way to the top. A split or missing tile means it no longer does, and the answer is to make it whole again before the next fire. That is the line between a note and a repair.
- A hairline split in one tile: often sealable if the rest is sound
- Offset or open joints: heat and sparks reach the brick
- Missing or crumbled sections: the flue is unlined there
- Heavy glazed buildup: the tile beneath cannot be judged until it is cleared
The usual flue fixes
Small damage in an otherwise good clay flue can be repaired in place, with a heat-rated coating or by resurfacing the inside. Where tiles are broken in several places, or the house was never lined, the fix is a new liner, usually stainless steel, running the full height. A gas appliance going into an old fireplace needs its own liner sized to it.
Every flue fix ends at the top. A new liner gets a screened cap, because the job is not done while embers can still get in or sparks can still get out. We write the cap into every relining plan so it is never left off.
What we publish, and what gets its own figure
A leak repair, a cricket and a gas insert vary within a known band from one house to the next, so they carry published ranges below. The cap is quoted after we measure. Relining, resurfacing, crown work, dampers and flashing alone depend on the chimney in front of us, and each gets its own written figure once the camera has run.
When the flue is why a fireplace failed, we write the work as a set: the flue fix, the cap above it and any leak that soaked the brick, in the order it should be done. Fire season sets that order more often than anything else, so an open top and a broken tile go first.
Published prices for common fixes
These come up often after a flue finding. Anything not listed gets a written figure on its own line.
- Camera inspection of the flue
- $375
- Gas insert on its own vent liner
- $2,650 to $5,350
- Finding and stopping water at the stack
- $535 to $3,200
- Diverter on the uphill side of the stack
- $430 to $965
- Uphill diverter plus new metal at every roof joint
- $645 to $1,600
- Screened cap fitted over the flue
- Quoted after we measure
Relining, flue resurfacing, crown, damper, chase cover and flashing-only work each get a written figure after the camera visit.
Flue repair questions
Can a cracked flue tile be patched?
Sometimes. One hairline split in otherwise sound tile can be sealed. Several cracks, open joints or missing pieces usually mean a liner. The frames on the report show which case you have.
Do I have to stop using the fireplace?
If the report marks the flue 'stop using', yes, until it is fixed. A broken flue lets heat reach wood it was built to keep away from.
Why does a gas insert need its own liner?
An old masonry flue is far larger than a gas unit needs, so the exhaust cools, condenses and lingers. A liner sized to the insert carries it up and out.
How does a buyer see that the flue was fixed?
We can run the camera again once the work is done and add the new frames to the file, so the buyer sees the finished flue rather than a receipt.